The 1700 models support high mix / medium volume throughput... at speeds up to 24 inches (60 centimeters) per minute, while conserving valuable factory floor space. Rapid response times and precise temperature controls assure process uniformity, regardless of component density or board loading, with identical profile performance in either air or nitrogen.
Highest Yields and Tight Process Control
Heller Industries Model 1826MK7 | ||
Model | 1826MK7 (Air) | 1826MK7 (Nitrogen) |
Electric Supply | ||
Power Input (3 Phase) Standard | 480 volts | 480 volts |
Breaker Size | 100 amps @ 480v | 100 amps @ 480v |
kW | 8 - 14 Continuous | 8 - 14 Continuous |
Typical Run Current | 25 - 35 amps @ 480v | 25 - 35 amps @ 480v |
Optional Power Inputs Available | 208/240/380/400/415/440/480 VAC | 208/240/380/400/415/440/480 VAC |
Frequency | 50/60 Hz | 50/60 Hz |
Sequential Zone Turn On | S | S |
Dimensions | ||
Overall Oven Dimensions | 183" (465cm) L x 60" (152cm) W x 57" (144cm) H | 183" (465cm) L x 60" (152cm) W x 57" (144cm) H |
Typical Net Weight | 4343 lbs. (1970 kg) | 4550 lbs. (2060 kg) |
Typical Shipping Weight | 5335 lbs. (2420 kg) | 5556 lbs. (2520 kg) |
Typical Shipping Dimension | 495 x 185 x 185 cm | 495 x 185 x 185 cm |
Computer Control | ||
AMD or Intel Based Computer | S | S |
Flat Screen Monitor w/Mount | S | S |
Windows Operating System | Windows 10 Home | Windows 10 Home |
Auto Start Software | S | S |
Data Logging | S | S |
Password Protection | S | S |
LAN Networking | O | O |
Inert Atmosphere | ||
Minimum PPM Oxygen | - | 10-25 PPM* |
Waterless Cooling w/ Flux | ||
Separation System | - | O |
Nitrogen On/Off Valve | - | O |
Oxygen Monitoring System | - | O |
Nitrogen Standby System | - | O |
Typical Nitrogen Consumption | - | 500 - 700 SCFH ** |
Additional Features | ||
KIC Profiling Software | S | S |
Signal Light Tower | S | S |
Powered Hood Lift | S | S |
Five (5)Thermocouple Profiling | S | S |
Redundant Alarm Sensors | O | O |
Intelligent Exhaust System | O | O |
KIC Profiler / ECD Profiler | O | O |
Center Board Support | O | O |
Board Drop Sensor | O | O |
Board Counter | O | O |
Bar Code Reader | O | O |
Custom Paint & Decal | O | O |
Battery Backup for Conveyor and PC | O | O |
GEM/SECS Interfacing | O | O |
Mesh Belt Conveyor | ||
Height From Floor | 36.6" + 2.4" (93 cm + 6 cm) | 36.6" + 2.4" (93 cm + 6 cm) |
Maximum PCB Width | 22" (56 cm) | 22" (56 cm) |
Space Required Between PCB's | 0.0" (0.0 cm) | 0.0" (0.0 cm) |
Conveyor Length On-Load | 18" (46 cm) * | 3" (7.5 cm) * |
Conveyor Length Off-Load | 18" (46 cm) * | 3" (7.5 cm) * |
Heated Tunnel Length | 109" (276 cm) | 109" (276 cm) |
Process Clearance Above Mesh Belt | 2.3" (5.8 cm) | 2.3" (5.8 cm) |
Mesh Belt Pitch | 0.5" (1.27 cm) | 0.5" (1.27 cm) |
Maximum Conveyor Speed | 74"/Min (188 cm/min.) | 74"/Min (188 cm/min.) |
Conveyor Direction Left to Right | S | S |
Conveyor Direction Right to Left | O | O |
Conveyor Speed Control | Closed Loop | Closed Loop |
Edge Hold Conveyor System Option | ||
Height from Floor - Standard | 37.8" ±2.4" (96 cm ± 6 cm) | 37.8" ±2.4" (96 cm ± 6 cm) |
Height from Floor - Optional | 35.4" ± 2.4" (90 cm ± 6 cm) |
35.4" ± 2.4" (90 cm ± 6 cm) |
Clearance Above & Below Conveyor Pins | 1.15" (2.9 cm) | 1.15" (2.9 cm) |
Length of PCB Support Pins | .187" (4.75 mm) | .187" (4.75 mm) |
3 mm long support pins | O | O |
Minimum/Maximum Board Width | 2" - 22" (5 - 56 cm) 24" (61cm) Optional** |
2" - 22" (5 - 56 cm) 24" (61cm) Optional** |
Power Width Adjustment | S | S |
Computer Controlled Width Adjust | O | O |
Auto Lubrication System | S | S |
Forced Convection Zones | ||
Top & Bottom | 8 | 8 |
Heater Type | Instant response open coil | Instant response open coil |
Heater Material | Nichrome | Nichrome |
Profile Change Time | 5 - 15 minutes | 5 - 15 minutes |
Temperature Control | ||
Accuracy of Temperature Controller | ± .1°C | ± .1°C |
Cross-Belt Temperature Tolerance | ±3.0°C | ±3.0°C |
Heater Wattage Per Zone | 5400 w*** | 5400 w*** |
Temperature Range Standard | 60-350°C | 60-350°C |
High Temperature Up to 450°C | O | O |
Cooling Systems | ||
Number of Cooling Zones Standard | 2 | 2 |
Cooling zone Length | 70cm | 75cm |
Additional Cooling Zones | O | O |
Water Cooling | - | O |
Notes: | S = Standard, O = Optional. |
Revolutionary Flux Management System Heller reflow oven has a revolutionary flux collection system that traps the flux in collection jars which can be easily removed and replaced while the reflow soldering oven is running - saving time consuming P.M. The new flux filtration box also has no risk of flux clogging for a longer-term P.M. interval. Additionally, our proprietary Flux-Free Grill system limits the flux residue on the cooling grills giving the Heller reflow oven system the highest production yields of any oven! |
------------FAQ----------------------------------------------------
Q: What we can do for you?
A: Total SMT Machines and Solution, professional Technical Support and Service.
Q:Are you a trade company or a manufacturer?
A: OEM & ODM service are available.
Q: What is your delivery date?
A: The delivery date is about 35 days after receipt of payment.